FL10094.3-R8
Report Status
Pending
Code Version
2023 Florida Building Code
Application Type
Affirmation
Folio:
Model:
26 Ga. 5V Roof Panel
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
26 Ga. 5V Roof Panel over APA Plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Locke Bowden - PE-49704
Validator:
Diane Marotta, P.E.
Official Site Status:
Validated
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 15, 2023
Validation Date:
October 15, 2023
Design Pressures:
-156.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 43 - Composite Roof Panels
CSI Code: 07 40 00 - Roofing and Siding Panels
Other:
-108.5 PSF @ 12" Fastener Spacing in panel rib. -156.5 PSF @ 6" Fastener Spacing in panel rib. Install per manufacturers details in compliance w/CURRENT FBC For use in HVHZ Zones.
Notes:
Date Submitted: October 15, 2023
Date Validated: October 15, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -108.5 PSF @ 12" Fastener Spacing in panel rib. -156.5 PSF @ 6" Fastener Spacing in panel rib. Install per manufacturers details in compliance w/CURRENT FBC For use in HVHZ Zones.
Official Site Status: Validated
Subcategory: Metal Roofing
Contact Information
Representative:
JASON NORTON
Address:
5846 Hwy 189,
BAKER, Florida 32531 USA
BAKER, Florida 32531 USA
Phone:
Website:
Listing Changes
Last Synced: 11/14/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes