FL10960.2-R3
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Affirmation
Folio:
Model:
BD1520 .040" x 34.5" coverage
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
BD1520 Pan & Batten System using .040" think aluminum. Base channels may be spaced up to 34.5 inches on center for a maximum coverage of 34.5".
Listing Details
Specifications
Submission Date:
February 9, 2018
Validation Date:
February 9, 2018
Possible CSI Codes:
CSI Code: 07 61 16 - Batten Seam Sheet Metal Roofing
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 05 33 23 - Aluminum Roof Decking
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 13 - Metal Roof Panels
Other:
When installed per UL 580 test report allowable uplift pressure is +/- 52.5 psf. Can not be used as a diaphragm. Fastener pullout/pullover failure modes to be evaluated by design engineer if metal deck supporting roof panels is less than 20-GA.
Notes:
Date Submitted: February 9, 2018
Date Validated: February 9, 2018
Entity:
Compliance Method: Test Report
Other: When installed per UL 580 test report allowable uplift pressure is +/- 52.5 psf. Can not be used as a diaphragm. Fastener pullout/pullover failure modes to be evaluated by design engineer if metal deck supporting roof panels is less than 20-GA.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Mike Boland
Address:
308 Connecticut Drive,
Burlington, New Jersey 08016 USA
Burlington, New Jersey 08016 USA
Phone:
Website:
Listing Changes
Last Synced: 06/17/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL10960 R3 II .040 PANEL INSTALLATION INSTRUCTIONS

PR TECH DOCS FL10960 R3 TR BD1520 UL 580 TEST REPORT

PR TECH DOCS FL10960 R3 TR UL 580-95 -06 EQUIVALENCE