FL10960.2-R3
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Affirmation
Folio:
Model:
BD1520 .040" x 34.5" coverage
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
BD1520 Pan & Batten System using .040" think aluminum. Base channels may be spaced up to 34.5 inches on center for a maximum coverage of 34.5".
Listing Details
Specifications
Submission Date:
February 9, 2018
Validation Date:
February 9, 2018
Possible CSI Codes:
CSI Code: 07 61 16 - Batten Seam Sheet Metal Roofing
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 05 33 23 - Aluminum Roof Decking
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 13 - Metal Roof Panels
Other:
When installed per UL 580 test report allowable uplift pressure is +/- 52.5 psf. Can not be used as a diaphragm. Fastener pullout/pullover failure modes to be evaluated by design engineer if metal deck supporting roof panels is less than 20-GA.
Notes:
Date Submitted: February 9, 2018
Date Validated: February 9, 2018
Entity:
Compliance Method: Test Report
Other: When installed per UL 580 test report allowable uplift pressure is +/- 52.5 psf. Can not be used as a diaphragm. Fastener pullout/pullover failure modes to be evaluated by design engineer if metal deck supporting roof panels is less than 20-GA.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Mike Boland
Address:
308 Connecticut Drive,
Burlington, New Jersey 08016 USA
Burlington, New Jersey 08016 USA
Phone:
Website:
Listing Changes
Last Synced: 10/12/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR TECH DOCS FL10960 R3 TR BD1520 UL 580 TEST REPORT

PR TECH DOCS FL10960 R3 TR UL 580-95 -06 EQUIVALENCE

PR INSTL DOCS FL10960 R3 II .040 PANEL INSTALLATION INSTRUCTIONS
QR Code To This Listing