FL13303.2-R12

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

FCM [04 or 08 or 14 or 29 or 89]

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Aluminum Curb Mount Fixed Skylight, size 2270 and smaller (426-H-701.43/.44)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
September 29, 2025
Validation Date:
September 30, 2025
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-100psf / +200psf
Possible CSI Codes:
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 63 16 - Pyramidal Metal-Framed Skylights
Other:
SKG-PG100, max. size 660mm x 1854mm (25.98" x 72.99"). PG100 means min. capacity is 100 psf. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 14 variant) on surface 2 / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm panes and 0.030" PVB interlayer (white for 08); with 2nd Lo-E coating on surface 4 for 29. Anchoring to site-built curb: 3 screws/side for longest members and 2/side for shorter members, fill all pre-punched holes with supplied screws
Notes:


Date Submitted: September 29, 2025

Date Validated: September 30, 2025

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: SKG-PG100, max. size 660mm x 1854mm (25.98" x 72.99"). PG100 means min. capacity is 100 psf. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 14 variant) on surface 2 / 8.5mm st. stl. spacer / 5.7mm laminate using two 2.5mm panes and 0.030" PVB interlayer (white for 08); with 2nd Lo-E coating on surface 4 for 29. Anchoring to site-built curb: 3 screws/side for longest members and 2/side for shorter members, fill all pre-punched holes with supplied screws

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 11/02/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL13303 R12 C CAC FL13303  FCM  2270 OR SMALLER 04 OR 08 OR 14 OR 29 OR 89
PR CERTIFICATE FL13303 R12 C CAC FL13303 FCM 2270 OR SMALLER 04 OR 08 OR 14 OR 29 OR 89
PR INSTL DOCS FL13303 R12 II FL13303 FCM INSTALLATION INSTRUCTIONS
PR INSTL DOCS FL13303 R12 II FL13303 FCM INSTALLATION INSTRUCTIONS
QR Code To This Listing
FL13303.2-R12 Listing QR Code
Shopping Cart