Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
29 ga. Stormproof panel over shingles and 15/32" plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Terrence E. Wolfe - PE-44923
Validator:
Gary Hartman, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
September 20, 2017
Validation Date:
September 27, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-153.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 10 71 16 - Storm Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 23 - Wood Roof Panels
Other:
-153.50 psf @ 1'-0" o.c Pattern B, -71.00 psf @ 2'-0" o.c. Pattern A The panel is a thru fastened roof panel installed over min. 15/32" plywood. Roof panels must be installed per manufacturer erection details.
Notes:
Date Submitted: September 20, 2017
Date Validated: September 27, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -153.50 psf @ 1'-0" o.c Pattern B, -71.00 psf @ 2'-0" o.c. Pattern A The panel is a thru fastened roof panel installed over min. 15/32" plywood. Roof panels must be installed per manufacturer erection details.