FL15156.3-R8
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:
1210 ALUM CLAD CASEMENT SINGLE *IG IMPACT*
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
CW-PG55-1054X2121 (42X84)-C
Listing Details
Specifications
Submission Date:
October 1, 2018
Validation Date:
October 26, 2018
Design Pressures:
-70psf / +55psf
Possible CSI Codes:
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 62 16 - Pyramidal Unit Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 16 - Pyramidal Metal-Framed Skylights
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
Other:
1" Insulated glass comprised of (1/8") annealed / (1/2") Super Spacer / (1/8") / .090 SGP / (1/8") annealed glass. The glass was set from the interior against back bedding. In addition a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300
Notes:
Date Submitted: October 1, 2018
Date Validated: October 26, 2018
Entity: Window and Door Manufacturer Association
Compliance Method: Certification Mark or Listing
Other: 1" Insulated glass comprised of (1/8") annealed / (1/2") Super Spacer / (1/8") / .090 SGP / (1/8") annealed glass. The glass was set from the interior against back bedding. In addition a back bed of silicone was used in the glazing pocket. GLASS MEETS ASTM E1300
Official Site Status: Approved
Subcategory: Casement
Contact Information
Representative:
Valerie Bach
Address:
829 N. 8th Street,
Medford, Wisconsin 54451 US
Medford, Wisconsin 54451 US
Phone:
Website:
Listing Changes
Last Synced: 05/16/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL15156 R8 II 85-7438-27

PR CERTIFICATE FL15156 R8 C CAC 1210 ALUM CLAD CASEMENT SINGLE IG IMPACT
QR Code To This Listing