FL16822.1-R4
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
PW-4000
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
PW-4000 Aluminum Picture Window, Fin.
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
Lucas A. Turner - PE-58201
Validator:
Steven M. Urich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 9, 2023
Validation Date:
October 10, 2023
Design Pressures:
-30psf / +30psf
Possible CSI Codes:
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 12 24 00 - Window Shades
CSI Code: 08 01 64 - Operation and Maintenance of Plastic-Framed Skylights
CSI Code: 08 64 00 - Plastic-Framed Skylights
Other:
Max. size 48" x 67", "O" config., 110" x 23", "OO" config. Installed on externally applied 2x wood bucks attached to concrete or poured walls. Glass conforms to ASTM E1300.
Notes:
Date Submitted: October 9, 2023
Date Validated: October 10, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Max. size 48" x 67", "O" config., 110" x 23", "OO" config. Installed on externally applied 2x wood bucks attached to concrete or poured walls. Glass conforms to ASTM E1300.
Official Site Status: Approved
Subcategory: Fixed
Contact Information
Representative:
Mary Rukashaza-Mukome
Address:
1900 SW 44th Avenue,
Ocala, Florida 34474 US
Ocala, Florida 34474 US
Phone:
Listing Changes
Last Synced: 10/07/2026
Change Log effective March 1st 2023