FL17643.6-R3

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

SL175

Database:
Florida Product Approval
Source Link:
Description:

Max 18" & min 10" wide, min 24 ga. steel or max 16" & min 10" wide, 0.032" thick aluminum standing seam panel fastened to nailable insulation over steel deck.

Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
  -  
Validator:
Bala Sockalingam, P.E.
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
UL LLC
Specifications
Submission Date:
February 22, 2018
Validation Date:
March 14, 2018
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-52.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 05 31 23 - Steel Roof Decking
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 16 - Insulated Metal Roof Panels
Other:
UL Construction No. 508A. Design uplift pressure with clips spaced @ 18" o.c. for aluminum panels and @ 36" o.c. for steel panels= 52.5 psf. The required design wind loads shall be determined for each project. The maximum clip spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code.
Notes:


Date Submitted: February 22, 2018

Date Validated: March 14, 2018

Entity: UL LLC

Compliance Method: Certification Mark or Listing

Other: UL Construction No. 508A. Design uplift pressure with clips spaced @ 18" o.c. for aluminum panels and @ 36" o.c. for steel panels= 52.5 psf. The required design wind loads shall be determined for each project. The maximum clip spacing listed herein shall not be exceeded. All rational analysis computations shall be prepared by a qualified design professional, as required by Florida Building Code.

Official Site Status: Approved

Subcategory: Metal Roofing
Contact Information
Representative:
Randy Blake
Address:
PO Box 229,
Fayetteville, North Carolina 28302 United States

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 03/13/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL17643 R3 C CAC SL175 SD CONST NO 508A
PR CERTIFICATE FL17643 R3 C CAC SL175 SD CONST NO 508A
PR INSTL DOCS FL17643 R3 II SL175 SD CONST NO 508A
PR INSTL DOCS FL17643 R3 II SL175 SD CONST NO 508A
QR Code To This Listing
FL17643.6-R3 Listing QR Code