FL17992.1-R4
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
Capital Rib Roof Panel
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Min. 29 Ga. Capital Rib Roof Panel over 1x4 Wood Purlins over 7/16" OSB
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Johnathan E. Green, P.E. - PE-88223
Validator:
Steven M. Urich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
September 24, 2023
Validation Date:
September 24, 2023
Design Pressures:
-123.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
Other:
Type 1: -41.7 psf @ 24" o.c. 1x4 Wood Purlin Spacing. Fastener Pattern: 9"-9"-9"-9". Type 2: -123.5 psf @ 24" o.c. 1x4 Wood Purlin Spacing. Fastener Pattern: 6"-3"-6"-3"-6"-3"-6". Install per manufacturer's details. Not for use in HVHZ Zones.
Notes:
Date Submitted: September 24, 2023
Date Validated: September 24, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Type 1: -41.7 psf @ 24" o.c. 1x4 Wood Purlin Spacing. Fastener Pattern: 9"-9"-9"-9". Type 2: -123.5 psf @ 24" o.c. 1x4 Wood Purlin Spacing. Fastener Pattern: 6"-3"-6"-3"-6"-3"-6". Install per manufacturer's details. Not for use in HVHZ Zones.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Larry Perry
Address:
629 S.E. Industrial Circle,
Lake City, Florida 32025
Lake City, Florida 32025
Phone:
Website:
Listing Changes
Last Synced: 11/14/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes