FL18386.1-R4
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
Mechanical Lock
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
1 1/2" Mechanical Lock over Plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Johnathan Green - PE-88223
Validator:
Steven M. Urich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 2, 2023
Validation Date:
October 3, 2023
Design Pressures:
-123.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 61 19 - Flat Seam Sheet Metal Roofing
CSI Code: 05 31 23 - Steel Roof Decking
CSI Code: 07 61 13 - Standing Seam Sheet Metal Roofing
Other:
-59.75 psf @ 24" o.c. -123.5 psf @ 6" o.c. Install per manufacturer's details. For use in HVHZ Zones.
Notes:
Date Submitted: October 2, 2023
Date Validated: October 3, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -59.75 psf @ 24" o.c. -123.5 psf @ 6" o.c. Install per manufacturer's details. For use in HVHZ Zones.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Natasha Bratt
Address:
719 Cattlemen Road,
Sarasota, Florida 34232
Sarasota, Florida 34232
Phone:
Listing Changes
Last Synced: 11/10/2026
Change Log effective March 1st 2023