FL19081.1-R3
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
ES-W425 Unitized Thermally Broken Window Wall System
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Non-impact resistant thermal unitized window wall system.
Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Storefronts
Evaluator:
Jalal Farooq - PE-81223
Validator:
Abel Carrasco, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 4, 2023
Validation Date:
October 5, 2023
Design Pressures:
-60psf / +60psf
Possible CSI Codes:
CSI Code: 08 44 26 - Structural Glass Curtain Walls
CSI Code: 08 46 00 - Window Wall Assemblies
CSI Code: 08 44 26.16 - Metal Framed Point Supported Glass Curtain Walls
CSI Code: 08 44 26.13 - Glass Framed Point Supported Glass Curtain Walls
CSI Code: 08 44 18 - Glazed Steel Curtain Walls
Other:
See installation drawing W15-80 for span vs load combinations and installation details.
Notes:
Date Submitted: October 4, 2023
Date Validated: October 5, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: See installation drawing W15-80 for span vs load combinations and installation details.
Official Site Status: Approved
Subcategory: Storefronts
Contact Information
Representative:
Andres Chamorro
Address:
10653 NE Quaybridge Ct.,
Miami, Florida 33138
Miami, Florida 33138
Phone:
Listing Changes
Last Synced: 11/08/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL19081 R3 II SS- ES-W425 UNITIZED THERMALLY BROKEN WW (NI) - DWG W15-80 (2023)

PR TECH DOCS FL19081 R3 AE SS-ES-W425 UNITIZED THERMALLY BROKEN WW (NI)-PAE 2023
QR Code To This Listing