FL19665.1-R5
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
EHH-601DE Hurricane Louver (Channel Frame)
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
6" Deep Horizontal Blade Louver with Channel Frame, Extruded Aluminum, Impact & Pressure Resistant with Option for High Velocity Wind Driven Rain Resistance
Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
Robert Nangia - PE-69555
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 19, 2023
Validation Date:
July 16, 2025
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 06 11 00 - Wood Framing
CSI Code: 05 25 00 - Aluminum Joist Framing
CSI Code: 07 42 23 - Wood Wall Panels
CSI Code: 07 70 00 - Roof and Wall Specialties and Accessories
CSI Code: 48 15 13 - Wind Turbines
Other:
Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Fully Closed VCD-40 Damper. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel, Aluminum & Wood. See FL19665.2 (Flange w/ Sleeve Frame) for Cracked Concrete Substrate.
Notes:
Date Submitted: October 19, 2023
Date Validated: July 16, 2025
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Allowable Stress Design (ASD). Rated for AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Fully Closed VCD-40 Damper. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel, Aluminum & Wood. See FL19665.2 (Flange w/ Sleeve Frame) for Cracked Concrete Substrate.
Official Site Status: Approved
Subcategory: Wall Louver
Contact Information
Representative:
Michael Steele
Address:
1110 Greenheck Drive (PO Box 410),
Schofield, Wisconsin 54476-0410 United States
Schofield, Wisconsin 54476-0410 United States
Phone:
Website:
Listing Changes
Last Synced: 08/09/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
None found
QR Code To This Listing