engineering plans logo black

FL21471.45-R8

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

AP138, AP138C, AP200, AP200C

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

1-3/8" or 2" thick insulated steel sandwich residential or commercial sectional garage door.

Listing Details
Category:
Doors
Subcategory:
Sectional Exterior Door Assemblies
Evaluator:
Scott A. Brown - PE-0065940
Validator:
John E. Scates, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
April 8, 2020
Validation Date:
April 8, 2020
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-55psf / +50psf
Possible CSI Codes:
CSI Code: 08 13 13.13 - Standard Hollow Metal Doors
CSI Code: 08 13 16 - Aluminum Doors
CSI Code: 08 11 13.13 - Standard Hollow Metal Doors and Frames
CSI Code: 08 13 16.13 - Aluminum Terrace Doors
CSI Code: 08 13 13 - Hollow Metal Doors
Other:
Max door width = 10'-0"
Notes:


Date Submitted: April 8, 2020

Date Validated: April 8, 2020

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Max door width = 10'-0"

Official Site Status: Approved

Subcategory: Sectional Exterior Door Assemblies
Manufacturer Info
Raynor Garage Doors, a family-owned company since 1944, manufactures and distributes high-quality residential and commercial garage doors and openers. With a wide variety of styles, materials, and customization options, Raynor offers durable and reliable garage door solutions for any need, backed by a strong commitment to customer satisfaction and industry-leading warranties. View all listings
* This manufacturer has not claimed their profile. Any logo or description displayed above has been generated by AI.
Contact Information
Representative:
Gary Wedekind
Address:
1101 East River Road, P.O. Box 448,
Dixon, Illinois 61021 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 12/11/2024
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL21471 R8 II P-2446-A
PR INSTL DOCS FL21471 R8 II P-2446-A
PR TECH DOCS FL21471 R8 AE PRODUCT EVALUATION 35-H
PR TECH DOCS FL21471 R8 AE PRODUCT EVALUATION 35-H
QR Code To This Listing
FL21471.45-R8 Listing QR Code
Shopping Cart