FL22696.1-R0
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
New
Folio:
Model:
Drexel Edge Termination Systems
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Edge termination systems for low-slope roofing systems
Listing Details
Category:
Roofing
Subcategory:
Roofing Accessories that are an Integral Part of the Roofing System
Evaluator:
Zachary R. Priest - PE-74021
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
July 30, 2017
Validation Date:
August 2, 2017
Design Pressures:
-215psf / +0psf
Possible CSI Codes:
CSI Code: 07 51 00 - Built-Up Bituminous Roofing
CSI Code: 07 72 00 - Roof Accessories
CSI Code: 07 30 00 - Steep Slope Roofing
CSI Code: 07 33 63 - Vegetated Steep-Slope Roofing
CSI Code: 07 72 73 - Vegetated Roof Systems
Other:
See evaluation report for limits of use.
Notes:
Date Submitted: July 30, 2017
Date Validated: August 2, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: See evaluation report for limits of use.
Official Site Status: Approved
Subcategory: Roofing Accessories that are an Integral Part of the Roofing System
Contact Information
Representative:
Jason Shumate
Address:
1234 Gardiner Lane,
LOUISVILLE, Kentucky 40213 United States
LOUISVILLE, Kentucky 40213 United States
Phone:
Website:
Listing Changes
Last Synced: 10/15/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL22696 R0 II 2017 FBC EVALUATION REPORT DRX14002.3 EDGE TERMINATION SYSTEMS-FINAL

PR TECH DOCS FL22696 R0 AE 2017 FBC EVALUATION REPORT DRX14002.3 EDGE TERMINATION SYSTEMS-FINAL
QR Code To This Listing