FL23953.11-R0
Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
New
Folio:
Model:
Snap-On Standing Seam Panel
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Standing Seam Roof Panels with Concealed Clips and Fasteners to Structural Support on Full Deck; With Snap-On Batten Cap over Clips and 1" High Legs.
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Locke Bowden - PE-49704
Validator:
Zachary R. Priest, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 16, 2017
Validation Date:
October 29, 2017
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 61 13 - Standing Seam Sheet Metal Roofing
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 61 16 - Batten Seam Sheet Metal Roofing
CSI Code: 05 31 23 - Steel Roof Decking
Other:
Not for use in HVHZ pending further testing for cyclic wind loading performance. An experienced and licensed designer should determine wind zone pressures, with appropriate adjustment factors to determine adequate application of this product to meet Florida requirements.24 Gage Steel: 1'-0"o.c. = 41.6 PSF.032" Aluminum: 1'-0"o.c. = 41.3 PSF
Notes:
Date Submitted: October 16, 2017
Date Validated: October 29, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Not for use in HVHZ pending further testing for cyclic wind loading performance. An experienced and licensed designer should determine wind zone pressures, with appropriate adjustment factors to determine adequate application of this product to meet Florida requirements.24 Gage Steel: 1'-0"o.c. = 41.6 PSF.032" Aluminum: 1'-0"o.c. = 41.3 PSF
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Nicholas Delfino
Address:
102 Northpoint Parkway Building 106,
Acworth, Georgia 30102 USA
Acworth, Georgia 30102 USA
Phone:
Listing Changes
Last Synced: 07/10/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL23953 R0 II FL 23953 PETERSEN ALUMINUM DETAIL BINDER SS

PR TECH DOCS FL23953 R0 AE FL 23953 PETERSEN ALUM REPORT COMPLETE-SS
QR Code To This Listing