Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
3 1/4" Thermally Broken 42" X 72"Aluminum Fixed Impact Window
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
-
Validator:
National Accreditation & Management Institute
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
National Accreditation & Management Institute
Specifications
Submission Date:
April 30, 2024
Validation Date:
April 30, 2024
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-50psf / +50psf
Possible CSI Codes:
CSI Code: 08 51 13 - Aluminum Windows
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 08 51 69 - Metal Storm Windows
CSI Code: 12 24 00 - Window Shades
CSI Code: 08 60 00 - Roof Windows and Skylights
Other:
Max 42" x 72" Fixed Window. AAMA AW-PG50-FW Rating. Missile Level D. Wind Zone 3. 1"Insulating Glass consisting of 1/4 Temp Ext. and 1/8" Ann x .090 PVB Interlayer x 1/8" Ann Lami Int. Max DLO 38 1/4" x 68 1/4. See Installation Drawings and Evaluation Report for Anchorage Details. 15psf Water. Glass meets ASTM E1300.
Notes:
Date Submitted: April 30, 2024
Date Validated: April 30, 2024
Entity: National Accreditation & Management Institute
Compliance Method: Certification Mark or Listing
Other: Max 42" x 72" Fixed Window. AAMA AW-PG50-FW Rating. Missile Level D. Wind Zone 3. 1"Insulating Glass consisting of 1/4 Temp Ext. and 1/8" Ann x .090 PVB Interlayer x 1/8" Ann Lami Int. Max DLO 38 1/4" x 68 1/4. See Installation Drawings and Evaluation Report for Anchorage Details. 15psf Water. Glass meets ASTM E1300.
Official Site Status: Approved
Subcategory: Fixed
Contact Information
Representative:
Fred Grunewald
Address:
PO Box 128 504 Highway 63 South, Freeburg, Missouri 65035 USA