engineering plans logo black

FL27453.1-R2

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:

Bison Wood Paver FS12-HW System

Database:
Florida Product Approval
Source Link:
Description:

Wood pavers supported on adjustable height pedestals providing an Independent Exterior Elevated Flooring System.

Listing Details
Category:
Components, Fasteners, Materials
Subcategory:
Products Introduced as a Result of New Technology
Evaluator:
John W. Knezevich, PE - PE-41961
Validator:
ORLANDO L. BLANCO, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 2 Option B
Entity:
 
Specifications
Submission Date:
October 22, 2020
Validation Date:
October 23, 2020
HVHZ Approved:
No
Impact Resistant:
[ None ]
Possible CSI Codes:
CSI Code: 07 76 00 - Roof Pavers
CSI Code: 07 76 16 - Roof Decking Pavers
CSI Code: 09 64 66 - Wood Athletic Flooring
CSI Code: 09 64 16 - Wood Block Flooring
CSI Code: 06 15 13 - Wood Floor Decking
Other:
These product evaluation documents shall be used by a licensed Architect or Engineer for specific applications. This system is NOT suitable for installation in the HVHZ. Reference Table 1 and General Note 6 of the product evaluation document to evaluate compliance with specific site conditions.
Notes:


Date Submitted: October 22, 2020

Date Validated: October 23, 2020

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: These product evaluation documents shall be used by a licensed Architect or Engineer for specific applications. This system is NOT suitable for installation in the HVHZ. Reference Table 1 and General Note 6 of the product evaluation document to evaluate compliance with specific site conditions.

Official Site Status: Approved

Subcategory: Products Introduced as a Result of New Technology
Contact Information
Representative:
Lisa von Gunten
Address:
701 Osage Street Bldg 2, Unit 120,
Denver, Colorado 80204

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/14/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL27453 R2 II BISON WOOD PAVER FS12-HW DRWGS DSS
PR INSTL DOCS FL27453 R2 II BISON WOOD PAVER FS12-HW DRWGS DSS
PR TECH DOCS FL27453 R2 AE BISON WOOD PAVER FS12-HW EVALUATION REPORT DSS
PR TECH DOCS FL27453 R2 AE BISON WOOD PAVER FS12-HW EVALUATION REPORT DSS

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL27453.1-R2 Listing QR Code
Shopping Cart