FL32994.20-R5
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
7.2 Panel (S3) 1' - 5' Spans
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
36" Wide x .050" (min.) Aluminum
Listing Details
Specifications
Submission Date:
September 20, 2023
Validation Date:
October 4, 2023
Design Pressures:
-192.1psf / +0psf
Possible CSI Codes:
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 05 33 23 - Aluminum Roof Decking
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 32 19 - Metal Roof Tiles
Other:
Allowable Wind Uplift Pressure, psf. Panel Span,ft: -192.10 @ 1', -162.20 @ 2', -132.40 @ 3', -102.50 @4', -72.75 @ 5'. Not for use in HVHZ. Safety Factor of 2.0is included.
Notes:
Date Submitted: September 20, 2023
Date Validated: October 4, 2023
Entity:
Compliance Method: Test Report
Other: Allowable Wind Uplift Pressure, psf. Panel Span,ft: -192.10 @ 1', -162.20 @ 2', -132.40 @ 3', -102.50 @4', -72.75 @ 5'. Not for use in HVHZ. Safety Factor of 2.0is included.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Nicholas Delfino
Address:
102 Northpoint Parkway Building 106,
Acworth, Georgia 30102 USA
Acworth, Georgia 30102 USA
Phone:
Listing Changes
Last Synced: 10/12/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL32994 R5 II INSTALLATION DETAILS ALL

PR INSTL DOCS FL32994 R5 II NEGATIVE LOAD TABLE 1 TO 5 FT SPANS

PR TECH DOCS FL32994 R5 TR ALL TEST REPORTS 1 FT TO 5 FT SPANS
QR Code To This Listing