FL32994.5-R1
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Affirmation
Folio:
Model:
PAC T-250 (A5)
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
16" Wide x 24 Ga. (min) Steel Panel w/Continuous Clips
Listing Details
Specifications
Submission Date:
October 14, 2020
Validation Date:
October 14, 2020
Design Pressures:
-119.85psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 63 - Fabricated Roof Panel Assemblies
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Uplift load of -98.80 PSF w/screw spacing of 60" o.c. and -119.85 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Notes:
Date Submitted: October 14, 2020
Date Validated: October 14, 2020
Entity:
Compliance Method: Test Report
Other: Uplift load of -98.80 PSF w/screw spacing of 60" o.c. and -119.85 PSF w/screw spacing of 24" o.c. Install per manufacturer's details. Not for use in HVHZ.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Nicholas Delfino
Address:
102 Northpoint Parkway Building 106,
Acworth, Georgia 30102 USA
Acworth, Georgia 30102 USA
Phone:
Listing Changes
Last Synced: 09/08/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL32994 R1 II T-250 INSTALLATION DETAILS

PR TECH DOCS FL32994 R1 TR T-250 E1592 24 GA. STEEL
QR Code To This Listing