FL33319.1-R1
Report Status
Pending
Code Version
2023 Florida Building Code
Application Type
Affirmation
Folio:
Model:
FF100 METAL ROOF PANEL
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
26GA STEEL SNAP-LOCK WITH PERFORATED NAIL STRIPTHREE [3] METHODS OF INSTALLATION
Listing Details
Specifications
Submission Date:
October 15, 2023
Validation Date:
October 15, 2023
Design Pressures:
-75psf / +0psf
Possible CSI Codes:
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 05 44 13 - Cold-Formed Metal Roof Trusses
CSI Code: 07 61 16 - Batten Seam Sheet Metal Roofing
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 13 - Metal Roof Panels
Other:
INSTALL AS TESTED. NOT FOR USE IN HVHZ ZONE. -75PSF
Notes:
Date Submitted: October 15, 2023
Date Validated: October 15, 2023
Entity:
Compliance Method: Test Report
Other: INSTALL AS TESTED. NOT FOR USE IN HVHZ ZONE. -75PSF
Official Site Status: Validated
Subcategory: Metal Roofing
Contact Information
Representative:
Norton Jason
Address:
4906 Hwy 45,
Eight Mile, Alabama 36613
Eight Mile, Alabama 36613
Phone:
Listing Changes
Last Synced: 11/09/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL33319 R1 II 1477T0003 REPORT UL 580 UL 1897 BAKER METALS FF100-2

PR TECH DOCS FL33319 R1 TR 1477T0003 REPORT UL 580 UL 1897 BAKER METALS FF100-2
QR Code To This Listing