FL37815.1-R0
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
New
Folio:
Model:
Advantage-Lok II
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Min 26 ga., 16" wide concealed fastened panel over 7/16" thick OSB & 15/32" & thick plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
February 14, 2021
Validation Date:
February 15, 2021
Design Pressures:
-131.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 63 - Fabricated Roof Panel Assemblies
Other:
Maximum uplift load of 131.5 psf @ seam fastener spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA rated plywood with retainer strap.
Notes:
Date Submitted: February 14, 2021
Date Validated: February 15, 2021
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Maximum uplift load of 131.5 psf @ seam fastener spacing of 4-5/8" o.c. along seam into min. 15/32" thick APA rated plywood with retainer strap.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Bernie Reed
Address:
19 E. Lincoln Drive NE,
Brookhaven, Mississippi 39601 USA
Brookhaven, Mississippi 39601 USA
Phone:
Listing Changes
Last Synced: 04/17/2026