engineering plans logo black

FL6393.2-R13

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

VELUX Sun Tunnel (14" Commercial) Impact Resistant

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

[TCC 014 or TGC 014 or TMC 014] + [1000] with diffuser: [THC 014 or TOC 014 or TTC 014] + [000*] // With or without an Energy Kit (* denotes 0, 2 or 3) (426-H-707.03)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
November 2, 2018
Validation Date:
November 28, 2018
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-50psf / +50psf
Possible CSI Codes:
CSI Code: 12 26 00 - Interior Daylighting Devices
CSI Code: 10 71 13.53 - Exterior Daylighting Devices
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 01 51 26 - Temporary Lighting
CSI Code: 26 51 23 - HID Interior Lighting
Other:
Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. [See following item for Air-water-structural approvals.]
Notes:


Date Submitted: November 2, 2018

Date Validated: November 28, 2018

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. dia. 356 mm (14 in). These models were tested for impact and cycling pursuant to ASTM E1996-05 and ASTM E1886-05. Dome glazing is minimum 3 mm thick. Flashing types attach either to site-built curb or directly to roof deck. Anchorage fasteners provided are black #8 st. stl. pan head screws. [See following item for Air-water-structural approvals.]

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/14/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL6393 R13 C CAC TCC TGC TMC 14 INCH COMMERCIAL SUN TUNNEL-IMPACT
PR CERTIFICATE FL6393 R13 C CAC TCC TGC TMC 14 INCH COMMERCIAL SUN TUNNEL-IMPACT
PR INSTL DOCS FL6393 R13 II TCC INSTALLATION
PR INSTL DOCS FL6393 R13 II TCC INSTALLATION
PR INSTL DOCS FL6393 R13 II TGC TMC INSTALLATION
PR INSTL DOCS FL6393 R13 II TGC TMC INSTALLATION
PR INSTL DOCS FL6393 R13 II THC DIFFUSER INSTALLATION
PR INSTL DOCS FL6393 R13 II THC DIFFUSER INSTALLATION
PR INSTL DOCS FL6393 R13 II TOC DIFFUSER INSTALLATION
PR INSTL DOCS FL6393 R13 II TOC DIFFUSER INSTALLATION
PR INSTL DOCS FL6393 R13 II TTC DIFFUSER INSTALLATION
PR INSTL DOCS FL6393 R13 II TTC DIFFUSER INSTALLATION

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL6393.2-R13 Listing QR Code
Shopping Cart