Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:
PBR Panel
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
26 GA PBR Roof Panel over Open Framing
Listing Details
Category:
Components, Fasteners, Materials
Subcategory:
Roof Deck
Evaluator:
Terrence E. Wolfe - PE-44923
Validator:
Brian Jaks, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
August 16, 2018
Validation Date:
August 17, 2018
Design Pressures:
-45psf / +60psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 43 - Composite Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 33 - Plastic Roof Panels
Other:
-45.0 psf. @ 5'-0" o.c. Fastener Pattern: 12"-12"-12". +60.0 psf. @ 5'-0" o.c. Fastener Pattern: 12"-12"-12". Install per Manufacturers details. Not for use in HVHZ Zones.
Notes:
Date Submitted: August 16, 2018
Date Validated: August 17, 2018
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -45.0 psf. @ 5'-0" o.c. Fastener Pattern: 12"-12"-12". +60.0 psf. @ 5'-0" o.c. Fastener Pattern: 12"-12"-12". Install per Manufacturers details. Not for use in HVHZ Zones.
Official Site Status: Approved
Subcategory: Roof Deck
Contact Information
Representative:
Tommy Connell
Address:
PO Box 417,
Adel, Georgia 31620
Adel, Georgia 31620
Phone:
Listing Changes
Last Synced: 03/11/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR INSTL DOCS FL6700 R4 II PBR ROOF PANEL DETAILS

PR TECH DOCS FL6700 R4 AE PBR STRUCTURAL ROOF PANEL NON HVHZ SEC
QR Code To This Listing