FL10015.1-R11

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:

HIG Aluminum Clad Wood Impact Casement Window

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

vent casement window (small and large missile impact)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Casement
Evaluator:
Warren W. Schaefer - PE-44135
Validator:
T.E. Lunn, PE, LLC
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
June 14, 2021
Validation Date:
June 15, 2021
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Possible CSI Codes:
CSI Code: 08 51 69 - Metal Storm Windows
CSI Code: 08 52 69 - Wood Storm Windows
CSI Code: 08 55 13 - Tornado-Resistant Windows
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 95 33 - Explosion Vents
Other:
Window size, pressure, assembly and installation requirements are to be as specified in the attached drawings No. 1518. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level D product. All glass meets the requirements of the current ASTM E1300 standard.
Notes:


Date Submitted: June 14, 2021

Date Validated: June 15, 2021

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Window size, pressure, assembly and installation requirements are to be as specified in the attached drawings No. 1518. Job required design wind pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level D product. All glass meets the requirements of the current ASTM E1300 standard.

Official Site Status: Approved

Subcategory: Casement
Contact Information
Representative:
Joe Hayden Sandi Robinson
Address:
102 Main St.,
Pella, Iowa 50219 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 02/16/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL10015 R11 II DRAWING 1518 (002)
PR INSTL DOCS FL10015 R11 II DRAWING 1518 (002)
PR TECH DOCS FL10015 R11 AE EVALUATION REPORT WWS-328 (002)
PR TECH DOCS FL10015 R11 AE EVALUATION REPORT WWS-328 (002)
QR Code To This Listing
FL10015.1-R11 Listing QR Code
Shopping Cart