FL10088.1-R10

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

EHH-601D Hurricane Louver

Database:
Florida Product Approval
Source Link:
Description:

6" Deep Horizontal Blade Louver, Extruded Aluminum, Hurricane Impact & Structural Resistant

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
Wayne K Helmila - PE-59092
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 16, 2023
Validation Date:
December 8, 2024
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 07 64 00 - Sheet Metal Wall Cladding
CSI Code: 05 14 00 - Structural Aluminum Framing
CSI Code: 07 46 19 - Steel Siding
CSI Code: 07 64 19 - Flat Seam Sheet Metal Wall Cladding
CSI Code: 07 46 16 - Aluminum Siding
Other:
Max +/- Design Pressure (ASD) per Panel Size: 150 = 43x144, 130 = 49.5x144, 105 = 61.5x144, 90 = 72x144. Rated to AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) w/o TAS 203 Cyclic. Rated to TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Louver w/o VCD-40 Damper is Not Rated to AMCA 550 (See FL10088.2). Channel Frame Substrates: Cracked Concrete, Grout Filled CMU, Steel & Wood. Flanged & Sleeved Frame Substrates: All Types via Anchorless Flange Capture.
Notes:


Date Submitted: October 16, 2023

Date Validated: December 8, 2024

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Max +/- Design Pressure (ASD) per Panel Size: 150 = 43x144, 130 = 49.5x144, 105 = 61.5x144, 90 = 72x144. Rated to AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) w/o TAS 203 Cyclic. Rated to TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Louver w/o VCD-40 Damper is Not Rated to AMCA 550 (See FL10088.2). Channel Frame Substrates: Cracked Concrete, Grout Filled CMU, Steel & Wood. Flanged & Sleeved Frame Substrates: All Types via Anchorless Flange Capture.

Official Site Status: Approved

Subcategory: Wall Louver
Contact Information
Representative:
Michael Steele
Address:
1110 Greenheck Drive (PO Box 410),
Schofield, Wisconsin 54476-0410 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/22/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
None found

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL10088.1-R10 Listing QR Code
Shopping Cart