Model:

EHH-601D Hurricane Louver with VCD-40 Damper

Database:
Florida Product Approval
Source Link:
Description:

6" Deep Horizontal Blade Louver with VCD-40 Damper, Extruded Aluminum, Hurricane High Velocity Wind Driven Rain Resistant, Hurricane Impact & Structural Hurricane Resistant

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
Wayne K Helmila - PE-59092
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 16, 2023
Validation Date:
December 8, 2024
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 10 71 16 - Storm Panels
CSI Code: 07 70 00 - Roof and Wall Specialties and Accessories
CSI Code: 10 71 16.16 - Movable Storm Panels
CSI Code: 07 42 00 - Wall Panels
CSI Code: 06 12 00 - Structural Panels
Other:
Max +/- Design Pressure (ASD) per Panel Size: 150 = 43x144, 130 = 49.5x144, 105 = 61.5x144, 90 = 72x144. Rated to AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) w/o TAS 203 Cyclic. Rated to TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550-22 with Fully Closed VCD-40 Damper. Channel Frame Substrates: Cracked Concrete, Grout Filled CMU, Steel & Wood. Flanged & Sleeved Frame Substrates: All Types via Anchorless Flange Capture.
Notes:


Date Submitted: October 16, 2023

Date Validated: December 8, 2024

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Max +/- Design Pressure (ASD) per Panel Size: 150 = 43x144, 130 = 49.5x144, 105 = 61.5x144, 90 = 72x144. Rated to AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) w/o TAS 203 Cyclic. Rated to TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550-22 with Fully Closed VCD-40 Damper. Channel Frame Substrates: Cracked Concrete, Grout Filled CMU, Steel & Wood. Flanged & Sleeved Frame Substrates: All Types via Anchorless Flange Capture.

Official Site Status: Approved

Subcategory: Wall Louver
Contact Information
Representative:
Michael Steele
Address:
1110 Greenheck Drive (PO Box 410),
Schofield, Wisconsin 54476-0410 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/22/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL10088 R10 II 10088 EHH-601D PE EVAL REPORT 11-15-2024
PR INSTL DOCS FL10088 R10 II 10088 EHH-601D PE EVAL REPORT 11-15-2024
PR INSTL DOCS FL10088 R10 II TBD
PR INSTL DOCS FL10088 R10 II TBD
PR TECH DOCS FL10088 R10 AE 10088 EHH-601D PE EVAL REPORT 11-15-2024
PR TECH DOCS FL10088 R10 AE 10088 EHH-601D PE EVAL REPORT 11-15-2024
PR TECH DOCS FL10088 R10 AE TBD
PR TECH DOCS FL10088 R10 AE TBD

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL10088.2-R10 Listing QR Code
Shopping Cart