FL10088.2-R10
Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:
EHH-601D Hurricane Louver with VCD-40 Damper
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
6" Deep Horizontal Blade Louver with VCD-40 Damper, Extruded Aluminum, Hurricane High Velocity Wind Driven Rain Resistant, Hurricane Impact & Structural Hurricane Resistant
Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
Wayne K Helmila - PE-59092
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Entity:
Specifications
Submission Date:
October 16, 2023
Validation Date:
December 8, 2024
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 10 71 16 - Storm Panels
CSI Code: 07 70 00 - Roof and Wall Specialties and Accessories
CSI Code: 10 71 16.16 - Movable Storm Panels
CSI Code: 07 42 00 - Wall Panels
CSI Code: 06 12 00 - Structural Panels
Other:
Max +/- Design Pressure (ASD) per Panel Size: 150 = 43x144, 130 = 49.5x144, 105 = 61.5x144, 90 = 72x144. Rated to AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) w/o TAS 203 Cyclic. Rated to TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550-22 with Fully Closed VCD-40 Damper. Channel Frame Substrates: Cracked Concrete, Grout Filled CMU, Steel & Wood. Flanged & Sleeved Frame Substrates: All Types via Anchorless Flange Capture.
Notes:
Date Submitted: October 16, 2023
Date Validated: December 8, 2024
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Max +/- Design Pressure (ASD) per Panel Size: 150 = 43x144, 130 = 49.5x144, 105 = 61.5x144, 90 = 72x144. Rated to AMCA 540 Enhanced Protection Missile Impact Level E (80 fps) w/o TAS 203 Cyclic. Rated to TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550-22 with Fully Closed VCD-40 Damper. Channel Frame Substrates: Cracked Concrete, Grout Filled CMU, Steel & Wood. Flanged & Sleeved Frame Substrates: All Types via Anchorless Flange Capture.
Official Site Status: Approved
Subcategory: Wall Louver
Contact Information
Representative:
Michael Steele
Address:
1110 Greenheck Drive (PO Box 410),
Schofield, Wisconsin 54476-0410 United States
Schofield, Wisconsin 54476-0410 United States
Phone:
Website:
Listing Changes
Last Synced: 11/17/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes