Integrity IMPACT Casement Round Top - IZ3, 407-H-1125.04 & 407-H-1125.03
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
-
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
December 31, 2020
Validation Date:
January 4, 2021
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-65psf / +55psf
Possible CSI Codes:
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 08 67 00 - Skylight Protection and Screens
CSI Code: 08 01 62 - Operation and Maintenance of Unit Skylights
CSI Code: 08 01 63 - Operation and Maintenance of Metal-Framed Skylights
CSI Code: 08 60 00 - Roof Windows and Skylights
Other:
Maximum size: 72" x 29". Wind zone 3 missile level D. All Glass Conforms to ASTM E 1300. Tested glass make-up (3.9mm T/9.5 mm airspace/ 6.9 mm PVB lami)