FL10531.20-R5

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:

SUR, SUL, SURC, SULC series hangers

Database:
Florida Product Approval
Source Link:
Description:

Skewed face-mount hangers available in widths ranging from 1-9/16" to 3-9/16" and heights ranging from 3-1/16" to 13-3/4". Concealed flange version (SURC, SULC) available for all double 2X and 4X models; only acute flange is concealed.

Listing Details
Category:
Components, Fasteners, Materials
Subcategory:
Wood Connectors
Evaluator:
  -  
Validator:
ICC Evaluation Services, LLC
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Product Evaluation Entity
Approval Method:
Method 1 Option C
Entity:
ICC Evaluation Service, LLC
Specifications
Submission Date:
December 23, 2020
Validation Date:
December 23, 2020
HVHZ Approved:
Yes
Impact Resistant:
[ None ]
Possible CSI Codes:
CSI Code: 21 05 29 - Hangers and Supports for Fire-Suppression Piping and Equipment
CSI Code: 22 05 29 - Hangers and Supports for Plumbing Piping and Equipment
CSI Code: 26 05 29 - Hangers and Supports for Electrical Systems
CSI Code: 23 05 29 - Hangers and Supports for HVAC Piping and Equipment
CSI Code: 27 05 29 - Hangers and Supports for Communications Systems
Other:
If SUR/L24 or SUR/L26 models are used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. For models with (2) joist nails, fill additional triangular joist nail holes or provide supplemental connectors to achieve minimum 700 lb. uplift. Web stiffeners are required with I-joists when filling triangular joist nail holes.
Notes:


Date Submitted: December 23, 2020

Date Validated: December 23, 2020

Entity: ICC Evaluation Service, LLC

Compliance Method: Evaluation Report from a Product Evaluation Entity

Other: If SUR/L24 or SUR/L26 models are used to resist wind uplift in HVHZ, supplemental connectors must be used to achieve minimum 700 lb. uplift. For models with (2) joist nails, fill additional triangular joist nail holes or provide supplemental connectors to achieve minimum 700 lb. uplift. Web stiffeners are required with I-joists when filling triangular joist nail holes.

Official Site Status: Approved

Subcategory: Wood Connectors
Contact Information
Representative:
N/A

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 08/20/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL10531 R5 II ESR-2552 (REVISED 12-20)
PR INSTL DOCS FL10531 R5 II ESR-2552 (REVISED 12-20)
PR TECH DOCS FL10531 R5 AE ESR-2552 (REVISED 12-20)
PR TECH DOCS FL10531 R5 AE ESR-2552 (REVISED 12-20)
QR Code To This Listing
FL10531.20-R5 Listing QR Code
Shopping Cart