Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
1.5" Snap Lock 24 Ga. 16" Wide Roof Panel over APA Plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Locke Bowden - PE-49704
Validator:
Hermes F. Norero, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
January 22, 2021
Validation Date:
April 12, 2021
HVHZ Approved:
Yes
Impact Resistant:
[ None ]
Design Pressures:
-116psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 23 - Wood Roof Panels
Other:
-86.0 psf @ 24" o.c. Clip Spacing. -108.5 psf @ 12" o.c. Clip Spacing. -116.0 psf @ 6" o.c. Clip Spacing. 15/32"APA plywood for Non HVHZ, Reroofing in HVHZ:add additional 15/32" APA plywood, HVHZ 19/32" APA plywood-new construction. Panel is Non structural. Install per manufacturers details in compliance w/FBC, For use in HVHZ Zones.
Notes:
Date Submitted: January 22, 2021
Date Validated: April 12, 2021
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -86.0 psf @ 24" o.c. Clip Spacing. -108.5 psf @ 12" o.c. Clip Spacing. -116.0 psf @ 6" o.c. Clip Spacing. 15/32"APA plywood for Non HVHZ, Reroofing in HVHZ:add additional 15/32" APA plywood, HVHZ 19/32" APA plywood-new construction. Panel is Non structural. Install per manufacturers details in compliance w/FBC, For use in HVHZ Zones.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
N/A