16" wide, nom 0.032" thick fastener roof panel over min 19/32 thick plywood deck
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
September 9, 2017
Validation Date:
September 14, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-195psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
Uplift load of 22.5 psf at fastener spacing of 24" o.c., 104.7 psf at fastener spacing of 6" o.c. and 195.0 psf at fastener spacing of 6" o.c. with support strap.
Notes:
Date Submitted: September 9, 2017
Date Validated: September 14, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 22.5 psf at fastener spacing of 24" o.c., 104.7 psf at fastener spacing of 6" o.c. and 195.0 psf at fastener spacing of 6" o.c. with support strap.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
David Stermer
Address: