Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
August 25, 2025
Validation Date:
August 25, 2025
HVHZ Approved:
Yes
Impact Resistant:
[ None ]
Design Pressures:
-154.7psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 43 - Composite Roof Panels
Other:
-60.5 psf at 12-12-12 Fastener Pattern at 24 O.C. Fastener Spacing. -154.75 psf at 7-5-7-5-7 Fastener Pattern at 12 O.C. Fastener Spacing 15/32"plywood over existing and 19/32" for new construction in HVHZ ZONES.INSTALL per manufacturer details and RAS 133. For use in HVHZ Zones.
Notes:
Date Submitted: August 25, 2025
Date Validated: August 25, 2025
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer