FL13145.10-R13

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

CUPCA SPIZ3 3684

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Clad Ultimate Push Out Casement StormPlus IZ3 3684 407-H-1121

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Casement
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
June 14, 2018
Validation Date:
August 21, 2018
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-65psf / +65psf
Possible CSI Codes:
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 63 19 - Vaulted Metal-Framed Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
Other:
Max Size 36" x 83 1/8" (914mm x 2111mm) Glass Makeup: nominal 19.1mm (0.752") insulating glass comprised of a 3.1mm (0.122") annealed exterior sheet, a 8.0mm (0.315") desiccant-filled metal spacer system and a 8.6mm (0.339") laminated interior sheet. The interior laminated sheet was comprised of two 3.1mm (0.122") annealed sheets and a 2.3mm (0.91") PVB interlayer. Glass complies with ASTM E1300
Notes:


Date Submitted: June 14, 2018

Date Validated: August 21, 2018

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: Max Size 36" x 83 1/8" (914mm x 2111mm) Glass Makeup: nominal 19.1mm (0.752") insulating glass comprised of a 3.1mm (0.122") annealed exterior sheet, a 8.0mm (0.315") desiccant-filled metal spacer system and a 8.6mm (0.339") laminated interior sheet. The interior laminated sheet was comprised of two 3.1mm (0.122") annealed sheets and a 2.3mm (0.91") PVB interlayer. Glass complies with ASTM E1300

Official Site Status: Approved

Subcategory: Casement
Contact Information
Representative:
Cheryl Hill
Address:
Hwy 11 West,
Warroad, Minnesota 56763 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/16/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL13145 R13 C CAC CCL FOR MARVIN 407-H-1121
PR CERTIFICATE FL13145 R13 C CAC CCL FOR MARVIN 407-H-1121
PR INSTL DOCS FL13145 R13 II 0087889
PR INSTL DOCS FL13145 R13 II 0087889
PR INSTL DOCS FL13145 R13 II INSTALL-FL13145-CUPCA-SPIZ3
PR INSTL DOCS FL13145 R13 II INSTALL-FL13145-CUPCA-SPIZ3
PR TECH DOCS FL13145 R13 AE EVALREPORT-FL13145-CUPCA-SPIZ3
PR TECH DOCS FL13145 R13 AE EVALREPORT-FL13145-CUPCA-SPIZ3

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL13145.10-R13 Listing QR Code
Shopping Cart