FL13300.3-R13

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

QPF [2006 or 2016 or 2017] (HVHZ)

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Pan Flashed Fixed Skylight, size 4646 and smaller

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
September 29, 2025
Validation Date:
September 30, 2025
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-50psf / +120psf
Possible CSI Codes:
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 67 00 - Skylight Protection and Screens
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
Other:
Wind Zone 4, Missile Level D, Cycle Pressure +50/-50, max. size 1219mm x 1219mm. This model was tested for cycling pursuant to ASTM standards. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. For anchorage details, see Page 6 of instructions.
Notes:


Date Submitted: September 29, 2025

Date Validated: September 30, 2025

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: Wind Zone 4, Missile Level D, Cycle Pressure +50/-50, max. size 1219mm x 1219mm. This model was tested for cycling pursuant to ASTM standards. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. For anchorage details, see Page 6 of instructions.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 03/15/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL13300 R13 C CAC FL13300 QPF [4646 OR SMALLER] 0006 OR 0016 OR 0017 IMPACT
PR CERTIFICATE FL13300 R13 C CAC FL13300 QPF [4646 OR SMALLER] 0006 OR 0016 OR 0017 IMPACT
PR INSTL DOCS FL13300 R13 II FL13300 QPF INSTALLATION INSTRUCTIONS
PR INSTL DOCS FL13300 R13 II FL13300 QPF INSTALLATION INSTRUCTIONS
QR Code To This Listing
FL13300.3-R13 Listing QR Code
Shopping Cart