FL13300.3-R6

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

QPF [2006 or 2016]

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Pan Flashed Fixed Skylight, size 4646 and smaller (426-H-677.07 and -677.09)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
July 9, 2020
Validation Date:
July 13, 2020
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-50psf / +50psf
Possible CSI Codes:
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 67 00 - Skylight Protection and Screens
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 53 - Motorized Metal-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
Other:
Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 1226mm x 1226mm. This model was tested for cycling pursuant to ASTM E 1886 and ASTM E1996. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. For anchorage details, see Page 6 of instructions.
Notes:


Date Submitted: July 9, 2020

Date Validated: July 13, 2020

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 1226mm x 1226mm. This model was tested for cycling pursuant to ASTM E 1886 and ASTM E1996. Glass meets ASTM E1300: 3mm clear tempered with Lo-E366 (or Lo-E340 for 2016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm heat-strengthened panes and three 0.030" PVB interlayers. For anchorage details, see Page 6 of instructions.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Mike Rhoden
Address:
P.O. Box 5001,
Greenwood, South Caroli 29648 USA
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 03/22/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL13300 R6 II QPF INSTALLATION INSTRUCTIONS 07.09.2020 452199-2020-06 L
PR INSTL DOCS FL13300 R6 II QPF INSTALLATION INSTRUCTIONS 07.09.2020 452199-2020-06 L
PR CERTIFICATE FL13300 R6 C CAC VELUX - 426-H-677.07 AND .09
PR CERTIFICATE FL13300 R6 C CAC VELUX - 426-H-677.07 AND .09
QR Code To This Listing
FL13300.3-R6 Listing QR Code
Shopping Cart