Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 1302mm x 1295mm.This model was tested for cycling pursuant to ASTM E 1886 and ASTM E 1996. Glass meets ASTM E1300: 3.9mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Notes:
Date Submitted: August 2, 2017
Date Validated: August 2, 2017
Entity: Window and Door Manufacturer Association
Compliance Method: Certification Mark or Listing
Other: Wind Zone 3, Missile Level C, Cycle Pressure +50/-50, max. size 1302mm x 1295mm.This model was tested for cycling pursuant to ASTM E 1886 and ASTM E 1996. Glass meets ASTM E1300: 3.9mm clear tempered / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.