Wind Zone 4, Missile D, Cycle Press. +50/-50, max. size 648mm x 1257mm (25.51" x 49.48"). Tested ASTM E1886/ASTM E1996, TAS 201/202/203. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 16 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: 3 screws/side for longest members & 2/side for shorter members. Fill all pre-punched holes with supplied screws.
Notes:
Date Submitted: July 13, 2023
Date Validated: July 13, 2023
Entity: Window and Door Manufacturer Association
Compliance Method: Certification Mark or Listing
Other: Wind Zone 4, Missile D, Cycle Press. +50/-50, max. size 648mm x 1257mm (25.51" x 49.48"). Tested ASTM E1886/ASTM E1996, TAS 201/202/203. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 16 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: 3 screws/side for longest members & 2/side for shorter members. Fill all pre-punched holes with supplied screws.