Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Wind Zone 3, Missile C, Cycle Press. +50/-50, max. size 1302mm x 1295mm. Tested for cycling per ASTM E1886 and ASTM E1996. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 0016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.
Notes:
Date Submitted: April 16, 2019
Date Validated: April 22, 2019
Entity: Window and Door Manufacturer Association
Compliance Method: Certification Mark or Listing
Other: Wind Zone 3, Missile C, Cycle Press. +50/-50, max. size 1302mm x 1295mm. Tested for cycling per ASTM E1886 and ASTM E1996. Glass meets ASTM E1300: 3.9mm clear tempered with Lo-E366 (or Lo-E340 for 0016 variant) on surface 2 / 7.5mm st. stl. spacer / 7mm laminate using two 2.3mm panes and three 0.030" PVB interlayers. Anchoring to site-built curb: three screws per side for longest members and two per side for shorter members, filling all pre-punched holes with supplied screws.