Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Max 16" wide, min. 26 ga. concealed fastener roof panel over min 15/32" thick plywood or min 7/16" thick OSB deck.
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Bala Sockalingam, P.E. - PE-62240
Validator:
Yoosef Lavi, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
September 2, 2023
Validation Date:
September 5, 2023
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-138.5psf / +0psf
Possible CSI Codes:
CSI Code: 05 31 23 - Steel Roof Decking
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 00 - Roof Panels
CSI Code: 05 33 23 - Aluminum Roof Decking
CSI Code: 06 15 16 - Wood Roof Decking
Other:
Uplift load of 56 psf at fastener spacing of 6.5" o.c. in 7/16" OSB. Uplift load of 78.5 psf at fastener spacing of 4.75" o.c. with structural sealant in 7/16" OSB. Uplift load of 138.5 psf at fastener spacing of 4.75" o.c. with structural sealant and exterior fasteners at 12" o.c. in 15/32" plywood.
Notes:
Date Submitted: September 2, 2023
Date Validated: September 5, 2023
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Uplift load of 56 psf at fastener spacing of 6.5" o.c. in 7/16" OSB. Uplift load of 78.5 psf at fastener spacing of 4.75" o.c. with structural sealant in 7/16" OSB. Uplift load of 138.5 psf at fastener spacing of 4.75" o.c. with structural sealant and exterior fasteners at 12" o.c. in 15/32" plywood.