engineering plans logo black

FL14696.35-R9

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Affirmation
Folio:
Model:

Twin Premium Impact Picture Window, Alternate Glass (1209,1210), Vertical Mullion

Database:
Florida Product Approval
Source Link:
Description:

CW-PG55-3645x2121 (144x84)

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Fixed
Evaluator:
  -  
Validator:
Window and Door Manufacturers Association
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
Window and Door Manufacturer Association
Specifications
Submission Date:
January 11, 2018
Validation Date:
January 11, 2018
Expiration Date:
12/31/2021
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-70psf / +55psf
Possible CSI Codes:
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 62 16 - Pyramidal Unit Skylights
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 08 62 13 - Domed Unit Skylights
Other:
(1") thick insulated glass comprised of 8mm (5/16) annealed / 6.3mm(1/4) Super Spacer / 4.7mm (3/16) / .090 SGP / 4.7mm (3/16) annealed glass and single nominal(23/32) thick Cardinal LG laminated glass comprised of (5/16) annealed / .090 SGP / (5/16) annealed glass. The glass was set from the interior againstsilicone back bedding. In addition, a back bed ofsilicone was used in the glazing pocket. Glass Meets ASTM E1300
Notes:


Date Submitted: January 11, 2018

Date Validated: January 11, 2018

Entity: Window and Door Manufacturer Association

Compliance Method: Certification Mark or Listing

Other: (1") thick insulated glass comprised of 8mm (5/16) annealed / 6.3mm(1/4) Super Spacer / 4.7mm (3/16) / .090 SGP / 4.7mm (3/16) annealed glass and single nominal(23/32) thick Cardinal LG laminated glass comprised of (5/16) annealed / .090 SGP / (5/16) annealed glass. The glass was set from the interior againstsilicone back bedding. In addition, a back bed ofsilicone was used in the glazing pocket. Glass Meets ASTM E1300

Official Site Status: Approved

Subcategory: Fixed
Contact Information
Representative:
Valerie Bach
Address:
829 N. 8th Street,
Medford, Wisconsin 54451 US
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/22/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR CERTIFICATE FL14696 R9 C CAC 1209-1210 PREMIUM IMPACT PICTURE TWIN
PR CERTIFICATE FL14696 R9 C CAC 1209-1210 PREMIUM IMPACT PICTURE TWIN
PR INSTL DOCS FL14696 R9 II 1209-1210 PREMIUM IMPACT PICTURE TWIN 85-7815-15.PDF
PR INSTL DOCS FL14696 R9 II 1209-1210 PREMIUM IMPACT PICTURE TWIN 85-7815-15.PDF

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL14696.35-R9 Listing QR Code
Shopping Cart