FL16164.1-R2

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

Double Timber Horizontal Mullion

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

Impact, HVHZ

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Mullions
Evaluator:
Luis Roberto Lomas - PE-62514
Validator:
Steven M. Urich, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
March 10, 2026
Validation Date:
March 15, 2026
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-70psf / +70psf
Possible CSI Codes:
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 62 16 - Pyramidal Unit Skylights
CSI Code: 08 67 00 - Skylight Protection and Screens
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
Other:
 
Notes:


Date Submitted: March 10, 2026

Date Validated: March 15, 2026

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other:  

Official Site Status: Approved

Subcategory: Mullions
Contact Information
Representative:
Michal Wasilewicz
Address:
Gerichtstrasse 23,
Berlin, Outside the 13347 Germany
Phone:
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information
Listing Changes
Last Synced: 10/21/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL16164 R2 II 08-01857A
PR INSTL DOCS FL16164 R2 II 08-01857A
PR TECH DOCS FL16164 R2 AE 512545A
PR TECH DOCS FL16164 R2 AE 512545A
QR Code To This Listing
FL16164.1-R2 Listing QR Code