Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
APP and SBS modified bitumen roof systems for use in FBC non-HVHZ jurisdictions.
Listing Details
Category:
Roofing
Subcategory:
Modified Bitumen Roof System
Evaluator:
-
Validator:
NEMO CERT, LLC (Validation)
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Approval Method:
Method 1 Option A
Entity:
UL LLC
Specifications
Submission Date:
November 17, 2023
Validation Date:
November 17, 2023
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-112.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 51 00 - Built-Up Bituminous Roofing
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 51 13 - Built-Up Asphalt Roofing
CSI Code: 07 72 73 - Vegetated Roof Systems
CSI Code: 07 71 00 - Roof Specialties
Other:
1.) The design pressure pertains to one assembly. Refer to UL TGIK Certification for all assemblies and pressures. 2.) The "Uplift Resistance" in UL TGIK listings reflects ultimate performance. Divide "Uplift Resistance" by 2 to obtain allowable design pressure. 3.) UL TGIK certification listings are limited to wind uplift resistance. This file does not purport to address codified physical property requirements of the roof membranes per FBC 1507.11.2.
Notes:
Date Submitted: November 17, 2023
Date Validated: November 17, 2023
Entity: UL LLC
Compliance Method: Certification Mark or Listing
Other: 1.) The design pressure pertains to one assembly. Refer to UL TGIK Certification for all assemblies and pressures. 2.) The "Uplift Resistance" in UL TGIK listings reflects ultimate performance. Divide "Uplift Resistance" by 2 to obtain allowable design pressure. 3.) UL TGIK certification listings are limited to wind uplift resistance. This file does not purport to address codified physical property requirements of the roof membranes per FBC 1507.11.2.
Official Site Status: Approved
Subcategory: Modified Bitumen Roof System
Contact Information
Representative:
David Allen
Address:
#2 Industrial Park Drive P.O. Box 497, Morrilton, Arkansas 72110 USA