Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
over 1X4 SYP Wood purlins over (one layer of shingles when permitted by local building department)over15/32" APA Plywood
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Locke Bowden - PE-49704
Validator:
Zachary R. Priest, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
October 19, 2017
Validation Date:
October 19, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
[ None ]
Design Pressures:
-146psf / +0psf
Possible CSI Codes:
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 06 15 16 - Wood Roof Decking
CSI Code: 07 54 13 - Copolymer-Alloy Roofing
Other:
-71.0 PSF @ 24" o.c. Fastener Pattern: 12"-12" -146.0PSF @ 24" o.c. in the flat of panels Fastener Pattern: 9.5" -2" -9.5" Install per manufacturers details. Not for use in HVHZ Zones.
Notes:
Date Submitted: October 19, 2017
Date Validated: October 19, 2017
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: -71.0 PSF @ 24" o.c. Fastener Pattern: 12"-12" -146.0PSF @ 24" o.c. in the flat of panels Fastener Pattern: 9.5" -2" -9.5" Install per manufacturers details. Not for use in HVHZ Zones.