FL16583.3-R5

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:

MSC Roof Panel

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

1. MSC 24", 24 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi2. MSC 24", 22 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi3. MSC 18", 24 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi4. MSC 18", 22 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi

Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
R. Keith Joyce - PE-59081
Validator:
Dennis Johnson, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 30, 2020
Validation Date:
November 3, 2020
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-52.5psf / +47psf
Possible CSI Codes:
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 01 70 - Operation and Maintenance of Roof Specialties and Accessories
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
1. Maximum roof component uplift pressure is 52.5 psf for a maximum span of 5'-0" based on UL 580 test results.2. Maximum roof component gravity load pressures are per load tables. 3. The panel is to be installed over open framing in accordance with Load Tables, Installation Details and UL Constructions. 4. The use of panels as a shear diaphragm is outside the scope of this product evaluation.5. Minimum installed roof slope is 0.25:12.
Notes:


Date Submitted: October 30, 2020

Date Validated: November 3, 2020

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: 1. Maximum roof component uplift pressure is 52.5 psf for a maximum span of 5'-0" based on UL 580 test results.2. Maximum roof component gravity load pressures are per load tables. 3. The panel is to be installed over open framing in accordance with Load Tables, Installation Details and UL Constructions. 4. The use of panels as a shear diaphragm is outside the scope of this product evaluation.5. Minimum installed roof slope is 0.25:12.

Official Site Status: Approved

Subcategory: Metal Roofing
Contact Information
Representative:
Dennis Johnson
Address:
PO Box 2078,
GRAND ISLAND, Nebraska 68802 United States

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/22/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL16583 R5 II MSC ROOF INSTALLATION DETAILS
PR INSTL DOCS FL16583 R5 II MSC ROOF INSTALLATION DETAILS
PR TECH DOCS FL16583 R5 AE MSC ROOF EVALUATION REPORT (10-06-20)
PR TECH DOCS FL16583 R5 AE MSC ROOF EVALUATION REPORT (10-06-20)
QR Code To This Listing
FL16583.3-R5 Listing QR Code
Shopping Cart