Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
1. MSC 24", 24 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi2. MSC 24", 22 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi3. MSC 18", 24 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi4. MSC 18", 22 Gauge, Min Fy = 50 ksi, Min Fu = 65 ksi
Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
R. Keith Joyce - PE-59081
Validator:
Dennis Johnson, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
October 30, 2020
Validation Date:
November 3, 2020
HVHZ Approved:
No
Impact Resistant:
Yes [FL]
Design Pressures:
-52.5psf / +47psf
Possible CSI Codes:
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 01 70 - Operation and Maintenance of Roof Specialties and Accessories
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
Other:
1. Maximum roof component uplift pressure is 52.5 psf for a maximum span of 5'-0" based on UL 580 test results.2. Maximum roof component gravity load pressures are per load tables. 3. The panel is to be installed over open framing in accordance with Load Tables, Installation Details and UL Constructions. 4. The use of panels as a shear diaphragm is outside the scope of this product evaluation.5. Minimum installed roof slope is 0.25:12.
Notes:
Date Submitted: October 30, 2020
Date Validated: November 3, 2020
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: 1. Maximum roof component uplift pressure is 52.5 psf for a maximum span of 5'-0" based on UL 580 test results.2. Maximum roof component gravity load pressures are per load tables. 3. The panel is to be installed over open framing in accordance with Load Tables, Installation Details and UL Constructions. 4. The use of panels as a shear diaphragm is outside the scope of this product evaluation.5. Minimum installed roof slope is 0.25:12.
Official Site Status: Approved
Subcategory: Metal Roofing
Contact Information
Representative:
Dennis Johnson
Address:
PO Box 2078, GRAND ISLAND, Nebraska 68802 United States