FL16781.1-R5

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

EACA-601D Hurricane Louver

Database:
Florida Product Approval
Source Link:
Description:

6" Deep Combination Louver-Damper, Horizontal Blade, Extruded Aluminum, Hurricane High Velocity Wind Driven Rain Resistant, Hurricane Impact & Structural Resistant

Listing Details
Category:
Storefront Curtainwall & Cladding
Subcategory:
Wall Louver
Evaluator:
Robert Nangia - PE-69555
Validator:
Locke Bowden P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
August 2, 2023
Validation Date:
April 24, 2024
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-110psf / +110psf
Possible CSI Codes:
CSI Code: 07 70 00 - Roof and Wall Specialties and Accessories
CSI Code: 10 71 16 - Storm Panels
CSI Code: 07 42 00 - Wall Panels
CSI Code: 10 71 16.16 - Movable Storm Panels
CSI Code: 08 91 16 - Operable Wall Louvers
Other:
Allowable Stress Design (ASD). Rated for AMCA 540 Basic Protection Missile Impact Level D (50 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Blades Fully Closed. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel, Aluminum & Wood.
Notes:


Date Submitted: August 2, 2023

Date Validated: April 24, 2024

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Allowable Stress Design (ASD). Rated for AMCA 540 Basic Protection Missile Impact Level D (50 fps) without TAS 203 Cyclic. Rated for TAS 201 Basic Missile Impact Level D (50 fps) with TAS 203 Cyclic. Passed AMCA 550 with Blades Fully Closed. Substrates Include: Concrete (Non-Cracked), Grout Filled CMU, Steel, Aluminum & Wood.

Official Site Status: Approved

Subcategory: Wall Louver
Contact Information
Representative:
Michael Steele
Address:
1110 Greenheck Drive (PO Box 410),
Schofield, Wisconsin 54476-0410 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/05/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL16781 R5 II FPA 16781 EACA-601D PE EVAL REPORT 2024-01-05
PR INSTL DOCS FL16781 R5 II FPA 16781 EACA-601D PE EVAL REPORT 2024-01-05