FL16804.11-R7
Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Revision
Folio:
Model:
Series 176 Vinyl HRP 1/4 - 1/2 - 1/4 Impact HVHZ
Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:
Series 176 Vinyl HRP 1/4 - 1/2 - 1/4 Impact HVHZ
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Horizontal Slider
Evaluator:
-
Validator:
National Accreditation & Management Institute
Official Site Status:
Approved
Compliance Method:
Certification Mark or Listing
Entity:
National Accreditation & Management Institute
Specifications
Submission Date:
February 9, 2023
Validation Date:
July 5, 2023
Possible CSI Codes:
CSI Code: 08 62 00 - Unit Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 12 24 16.13 - Z-Pleated Window Shades
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 08 60 00 - Roof Windows and Skylights
Other:
Maximum Size: 111" x 63", Flange Installation Design Pressure: +50.0/-65.0PSF, Nailing Fin Installation Design Pressure: +55.0/-60.0PSF, Approved Configuration XOX.FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1). GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS.WHEN USED IN THE HVHZ OUTBOARD LITE MUST BE TEMPERED GLASS.
Notes:
Date Submitted: February 9, 2023
Date Validated: July 5, 2023
Entity: National Accreditation & Management Institute
Compliance Method: Certification Mark or Listing
Other: Maximum Size: 111" x 63", Flange Installation Design Pressure: +50.0/-65.0PSF, Nailing Fin Installation Design Pressure: +55.0/-60.0PSF, Approved Configuration XOX.FRAME MATERIAL TO BE RIGID PVC FROM DECEUNINCK NORTH AMERICA AAMA CERTIFIED (DEP-1). GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS.WHEN USED IN THE HVHZ OUTBOARD LITE MUST BE TEMPERED GLASS.
Official Site Status: Approved
Subcategory: Horizontal Slider
Contact Information
Representative:
James Flesher
Address:
16341 Domestic Ave.,
Ft. Myers, Florida 33912
Ft. Myers, Florida 33912
Phone:
Listing Changes
Last Synced: 03/16/2026
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents

PR CERTIFICATE FL16804 R7 C CAC NI012196.02-R2

PR CERTIFICATE FL16804 R7 C CAC NI012196.03-R2

PR INSTL DOCS FL16804 R7 II 08-02536B

PR TECH DOCS FL16804 R7 AE 513308C
QR Code To This Listing