Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
April 26, 2024
Validation Date:
April 29, 2024
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Design Pressures:
-80psf / +80psf
Possible CSI Codes:
CSI Code: 08 01 60 - Operation and Maintenance of Skylights and Roof Windows
CSI Code: 08 60 00 - Roof Windows and Skylights
CSI Code: 08 67 00 - Skylight Protection and Screens
CSI Code: 12 24 00 - Window Shades
CSI Code: 08 01 64 - Operation and Maintenance of Plastic-Framed Skylights
Other:
Window size, assembly and installation requirements are to be as specified in the attached drawing No. 1880. Job required design window pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "E" product and may be used with essential facilities. All glass meets the requirements of the current ASTM E1300 standard.
Notes:
Date Submitted: April 26, 2024
Date Validated: April 29, 2024
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: Window size, assembly and installation requirements are to be as specified in the attached drawing No. 1880. Job required design window pressure shall be calculated in accordance with the Florida Building Code Chapter 16 and ASCE 7 Minimum Design Loads for Buildings and Other Structures. This window system is rated as a wind zone 4 missile level "E" product and may be used with essential facilities. All glass meets the requirements of the current ASTM E1300 standard.