FL17419.6-R2

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Affirmation
Folio:
Model:

Non-Insulated Door

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

CP0020 Slat

Listing Details
Category:
Doors
Subcategory:
Roll-Up Exterior Door Assemblies
Evaluator:
Shawn Patrick Kelley - PE-58299
Validator:
Gordon Thomas, P.E.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
October 9, 2017
Validation Date:
October 9, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-100psf / +100psf
Possible CSI Codes:
CSI Code: 08 17 00 - Integrated Door Opening Assemblies
CSI Code: 08 01 17 - Operation and Maintenance of Integrated Door Opening Assemblies
CSI Code: 08 17 33 - Integrated Plastic Door Opening Assemblies
CSI Code: 08 17 43 - Integrated Composite Door Opening Assemblies
CSI Code: 08 17 13 - Integrated Metal Door Opening Assemblies
Other:
Refer to DWG ES 16-62-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.
Notes:


Date Submitted: October 9, 2017

Date Validated: October 9, 2017

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Refer to DWG ES 16-62-CIW for maximum design pressure for each door width. The maximum height for all doors is 30 ft. Maximum design pressure is 100 psf. Mounting to steel jamb, concrete jamb, or filled CMU jamb. Slat material is available in galvanized or stainless steel.

Official Site Status: Approved

Subcategory: Roll-Up Exterior Door Assemblies
Contact Information
Representative:
RICHARD MAGGIO
Address:
24 Elmwood Avenue,
Mountaintop, Pennsylvania 18707 United States
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 07/08/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL17419 R2 II S-S INSTALL CIW
PR INSTL DOCS FL17419 R2 II S-S INSTALL CIW
PR TECH DOCS FL17419 R2 AE S-S ES-16-62-CIW
PR TECH DOCS FL17419 R2 AE S-S ES-16-62-CIW
PR TECH DOCS FL17419 R2 AE S-S EVAL REPORT CIW
PR TECH DOCS FL17419 R2 AE S-S EVAL REPORT CIW
QR Code To This Listing
FL17419.6-R2 Listing QR Code
Shopping Cart