Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
17.5mm thick laminated glass (2 sheets of 8mm tempered glass with 1.52 mm PVB interlayer).
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
Ethan A. Charpentier - PE-65106
Validator:
Scott Wolters, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
January 29, 2019
Validation Date:
January 31, 2019
Expiration Date:
12/31/2021
HVHZ Approved:
Yes
Impact Resistant:
No [FL]
Design Pressures:
-125psf / +125psf
Possible CSI Codes:
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 04 23 19 - Glass Unit Masonry Skylights
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
Other:
The pressures shown above are factored (LRFD).The un-factored design pressure limit (ASD) is 125(0.6) = +/-75 psf. This system utilizes Saflex PVB laminate documented in NOA #17-0712.05. System may not be used to enclose a space or be part of the building envelope, but rather is confined to open applications such as canopies, etc... that are attached to the building envelope. Stand-alone applications fall outside the scope of the state product approval program.
Notes:
Date Submitted: January 29, 2019
Date Validated: January 31, 2019
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: The pressures shown above are factored (LRFD).The un-factored design pressure limit (ASD) is 125(0.6) = +/-75 psf. This system utilizes Saflex PVB laminate documented in NOA #17-0712.05. System may not be used to enclose a space or be part of the building envelope, but rather is confined to open applications such as canopies, etc... that are attached to the building envelope. Stand-alone applications fall outside the scope of the state product approval program.
Official Site Status: Approved
Subcategory: Skylight
Contact Information
Representative:
Scott Knoblock
Address:
W126 N8585 Westbrook Crossing, Menomonee Falls, Wisconsin 53051