FL17478.2-R4

Report Status
Approved
Code Version
2023 Florida Building Code
Application Type
Revision
Folio:
Model:

21.5mm PSG System

Manufacturer:
Database:
Florida Product Approval
Source Link:
Description:

21.5mm thick laminated, point supported glass (2 layers of 10mm thick fully tempered glass with 1.52mm thick PVB interlayer).

Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
Mahmoud Maamouri - PE-77169
Validator:
Scott Wolters, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
July 25, 2024
Validation Date:
August 18, 2024
HVHZ Approved:
Yes
Impact Resistant:
No [FL]
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 04 23 19 - Glass Unit Masonry Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
Other:
The pressures shown above are factored (LRFD). The unfactored design pressure limit (ASD) is 150(0.6) = +/-90 psf. The system may not be used to enclose a space or be part of the building envelope, but rather is limited to open applications such as canopies, that are attached to the building envelope. Stand-alone applications fall outside the scope of the state product approval program. For size/shape limitations of glass, refer to Section 4.2 or Drawing 100 of the Evaluation Report.
Notes:


Date Submitted: July 25, 2024

Date Validated: August 18, 2024

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: The pressures shown above are factored (LRFD). The unfactored design pressure limit (ASD) is 150(0.6) = +/-90 psf. The system may not be used to enclose a space or be part of the building envelope, but rather is limited to open applications such as canopies, that are attached to the building envelope. Stand-alone applications fall outside the scope of the state product approval program. For size/shape limitations of glass, refer to Section 4.2 or Drawing 100 of the Evaluation Report.

Official Site Status: Approved

Subcategory: Skylight
Contact Information
Representative:
Scott Knoblock
Address:
W126 N8585 Westbrook Crossing,
Menomonee Falls, Wisconsin 53051
Search the National Fenestration Rating Council
(NFRC) for Energy Efficiency information

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 09/19/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL17478 R4 II 2024-07-25 INSTALLATION INSTRUCTIONS - SEALED AND DIGITALLY SIGNED
PR INSTL DOCS FL17478 R4 II 2024-07-25 INSTALLATION INSTRUCTIONS - SEALED AND DIGITALLY SIGNED
PR TECH DOCS FL17478 R4 AE 2024-07-25 NOVUM EVALUATION REPORT-R0 - SEALED AND DIGITALLY SIGNED
PR TECH DOCS FL17478 R4 AE 2024-07-25 NOVUM EVALUATION REPORT-R0 - SEALED AND DIGITALLY SIGNED
QR Code To This Listing
FL17478.2-R4 Listing QR Code
Shopping Cart