Search from thousands of Florida, Miami-Dade & other Engineering Plans. Search all at once, save, share, & monitor listings, all for free. Sign Up - Look inside Approval content with our DeepSearch reports - Learn More
21.5mm thick laminated, point supported glass (2 layers of 10mm thick fully tempered glass with 1.52mm thick PVB interlayer).
Listing Details
Category:
Windows Mullions and Skylights
Subcategory:
Skylight
Evaluator:
Mahmoud Maamouri - PE-77169
Validator:
Scott Wolters, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
Specifications
Submission Date:
July 25, 2024
Validation Date:
August 18, 2024
HVHZ Approved:
Yes
Impact Resistant:
No [FL]
Design Pressures:
-150psf / +150psf
Possible CSI Codes:
CSI Code: 08 64 00 - Plastic-Framed Skylights
CSI Code: 08 63 23 - Ridge Metal-Framed Skylights
CSI Code: 04 23 19 - Glass Unit Masonry Skylights
CSI Code: 08 63 00 - Metal-Framed Skylights
CSI Code: 08 63 13 - Domed Metal-Framed Skylights
Other:
The pressures shown above are factored (LRFD). The unfactored design pressure limit (ASD) is 150(0.6) = +/-90 psf. The system may not be used to enclose a space or be part of the building envelope, but rather is limited to open applications such as canopies, that are attached to the building envelope. Stand-alone applications fall outside the scope of the state product approval program. For size/shape limitations of glass, refer to Section 4.2 or Drawing 100 of the Evaluation Report.
Notes:
Date Submitted: July 25, 2024
Date Validated: August 18, 2024
Entity:
Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Other: The pressures shown above are factored (LRFD). The unfactored design pressure limit (ASD) is 150(0.6) = +/-90 psf. The system may not be used to enclose a space or be part of the building envelope, but rather is limited to open applications such as canopies, that are attached to the building envelope. Stand-alone applications fall outside the scope of the state product approval program. For size/shape limitations of glass, refer to Section 4.2 or Drawing 100 of the Evaluation Report.
Official Site Status: Approved
Subcategory: Skylight
Contact Information
Representative:
Scott Knoblock
Address:
W126 N8585 Westbrook Crossing, Menomonee Falls, Wisconsin 53051