FL17617.2-R1

Report Status
Approved
Code Version
2017 Florida Building Code
Application Type
Revision
Folio:
Model:

Imperial Rib Panel

Database:
Florida Product Approval
Source Link:
Description:

29 ga. Imperial Rib panel over min. 19/32" plywood

Listing Details
Category:
Roofing
Subcategory:
Metal Roofing
Evaluator:
Terrence E. Wolfe - PE-44923
Validator:
Gary Hartman, PE
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
September 21, 2017
Validation Date:
September 29, 2017
Expiration Date:
12/31/2021
HVHZ Approved:
No
Impact Resistant:
No [FL]
Design Pressures:
-52.5psf / +0psf
Possible CSI Codes:
CSI Code: 07 41 00 - Roof Panels
CSI Code: 07 41 13 - Metal Roof Panels
CSI Code: 07 41 23 - Wood Roof Panels
CSI Code: 07 61 00 - Sheet Metal Roofing
CSI Code: 07 63 00 - Sheet Metal Roofing Specialties
Other:
-52.50 psf @ 2'-0" o.c. The panel is a thru fastened roof panel installed over min. 19/32" plywood in accordance with UL construction # 560. Roof panels must be installed per manufacturer erection details
Notes:


Date Submitted: September 21, 2017

Date Validated: September 29, 2017

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: -52.50 psf @ 2'-0" o.c. The panel is a thru fastened roof panel installed over min. 19/32" plywood in accordance with UL construction # 560. Roof panels must be installed per manufacturer erection details

Official Site Status: Approved

Subcategory: Metal Roofing
Manufacturer Info
American Building Components (ABC) is a prefabricated construction company that utilizes advanced technology to deliver modular buildings, multi-family housing, commercial structures, and government facilities. Their streamlined process reduces construction time, ensures higher quality, and minimizes environmental impact. View all listings
* This manufacturer has not claimed their profile. Any logo or description displayed above has been generated by AI.
Contact Information
Representative:
Jason Allen
Address:
6975 Danville Road,
Nicholasville, Kentucky 40356

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 05/09/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL17617 R1 II IMPERIAL RIB DETAIL
PR INSTL DOCS FL17617 R1 II IMPERIAL RIB DETAIL
PR TECH DOCS FL17617 R1 AE IMPERIAL RIB - SECURED
PR TECH DOCS FL17617 R1 AE IMPERIAL RIB - SECURED
QR Code To This Listing
FL17617.2-R1 Listing QR Code
Shopping Cart