engineering plans logo black

FL1850.3-R14

Report Status
Approved
Code Version
2020 Florida Building Code
Application Type
Editorial Change
Folio:
Model:

Bertha HV Accordion Shutter - Blade 1 Only (HVHZ) - Drwg# 20-169

Database:
Florida Product Approval
Source Link:
Description:

Extruded aluminum interlocking blades retained by tracks (top and bottom) for storm protection

Listing Details
Category:
Impact Protection Devices
Subcategory:
Accordion
Evaluator:
Walter A. Tillit, Jr., P.E. - PE-44167
Validator:
John Henry Kampmann Jr.
Official Site Status:
Approved
Compliance Method:
Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Approval Method:
Method 1 Option D
Entity:
 
Specifications
Submission Date:
February 22, 2021
Validation Date:
March 15, 2021
HVHZ Approved:
Yes
Impact Resistant:
Yes [FL]
Possible CSI Codes:
CSI Code: 08 11 69.23 - Aluminum Storm Doors and Frames
CSI Code: 05 15 13 - Aluminum Wire Rope Assemblies
CSI Code: 08 12 16 - Aluminum Frames
CSI Code: 05 14 00 - Structural Aluminum Framing
CSI Code: 10 26 16.16 - Protective Corridor Handrails
Other:
Large missile level D. Max. span is 16-0 and 14-9 for 30 psf ASD negative load depending on centermates and locking rod configuration for the HV1 blade, 8'-0 for +64, -72 psf load for HV blade for Keystone mountings 7'-0 for +75, -75 psf for metals stud mountings and 8-0 for 110 psf. for HV1 and HV1A working in unison. See sheets 7, 11, 20 and 19 respectively of installation drawings for other spans and pressures.
Notes:


Date Submitted: February 22, 2021

Date Validated: March 15, 2021

Entity:  

Compliance Method: Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer

Other: Large missile level D. Max. span is 16-0 and 14-9 for 30 psf ASD negative load depending on centermates and locking rod configuration for the HV1 blade, 8'-0 for +64, -72 psf load for HV blade for Keystone mountings 7'-0 for +75, -75 psf for metals stud mountings and 8-0 for 110 psf. for HV1 and HV1A working in unison. See sheets 7, 11, 20 and 19 respectively of installation drawings for other spans and pressures.

Official Site Status: Approved

Subcategory: Accordion
Contact Information
Representative:
Bill Feeley
Address:
4268 Westroads Drive,
West Palm Beach, Florida 33407 USA

Read, ask experts, & comment on this topic. All for free.

Latest Posts From This Product Category

Ask The Circle
Listing Changes
Last Synced: 06/02/2025
Change Log effective March 1st 2023
Please sign in or create an account to view listing changes
Approval & Installation Documents
PR INSTL DOCS FL1850 R14 II H.V. ACCORDION SHUTTER SYSTEM BLADE 1 INSTALLATION INSTRUCTIONS HVHZ
PR INSTL DOCS FL1850 R14 II H.V. ACCORDION SHUTTER SYSTEM BLADE 1 INSTALLATION INSTRUCTIONS HVHZ
PR TECH DOCS FL1850 R14 AE H.V. ACCORDION SHUTTER SYSTEM BLADE 1 EVALUATION REPORT
PR TECH DOCS FL1850 R14 AE H.V. ACCORDION SHUTTER SYSTEM BLADE 1 EVALUATION REPORT

Your Ad on 100K+ Listings Contact Us
QR Code To This Listing
FL1850.3-R14 Listing QR Code
Shopping Cart